If you find any damage, immediately contact the last carrier. Residence time and helps quench licking exhaust flames ADJUSTING THE CONTROL Set the control to maintain as low a draft as will give good combustion and meet the requirements for heat. 1 Barometric draft control 1 Side exhaust pipe collar (front flue units only) 1 Direct intake collar (AFII burner units only) Check the components for shipping damage. Barometric damper The draft on the fire is affected by the height of the chimney, the temperature of the flue gases and the temperature and wind speed of the.
ADJUSTING BAROMETRIC DRAFT CONTROL INSTALL
We install manual Key Dampers as close to the stoveĬollar as possible. Stove can cause barometric damper to “BLOW-OUT.” Installations, as occasional gas explosions within the The bracket is marked 2, 4, 6 and 8, which indicates draft settings of. Turn the adjustment weight counterclockwise to loosen, then slide in slot to the proper position and tighten. This is extremely important on COAL stove Set the control to maintain as low a draft as will give good combustion and meet the requirements for heat. An inspection mirror is very handyĭamper is plum and level, secure in TEE with a #8 TEK On Field controls “AF & RC.” Even in extremely tightįirebox settings a barometric damper can always be The Field Type M+MG2 Draft Control provides precise draft regulations for solid fuels, oil, gas, or oil/gas appliances requiring only the simplest. PlaceĪ mason’s line level on the V adjustment knob found only Technique that ensures true horizontal levelness. Make sure that the draft control is plum and level, theįront face is exactly vertical, and that the hinge pinsĪre in exact horizontal plane. The right are designed for use where a TEE is provided. Precision calibrated at the factory for both

ADJUSTING BAROMETRIC DRAFT CONTROL PDF
Represent the “State of the Art” in draft controls,įeaturing heavy duty construction with high sensitivity. Draft Adjustment Procedure (Oil) View online or download PDF (1001 KB) Tjernlund SideShot SS1, SS1 SIDESHOT WITH UC1 UNIVERSAL CONTROL (VERSION X.04) 8504102 REV C 0204 User manual SideShot SS1, SS1 SIDESHOT WITH UC1 UNIVERSAL CONTROL (VERSION X. The Field Type M+MG2 Draft Control provides precise draft regulations for solid fuels, oil. They increase residence time of gases within theįirebox, enhancing combustion. Turn the knurled knob counter clockwise for less draft or clockwise to increase draft. The Type M features an infinitely variable screw adjustment. features an infinitely variable screw adjustment. Hard to believe that such a simple device can do amazing things!įor more information on the Field Controls MG-1 or to order the double-acting barometric damper, visit the NCI store at /MG-1.Dampers prevent appliance over- firing due to excessĭraft. negated by the use of a barometric draft control located between the draft inducer or power venter. It can also maintain equipment efficiency when there is excessive draft. On sealed flues, such as on induced draft equipment, this also regulates combustion air to the burner. The same holds true if the flue becomes restricted or blocked. If the draft drops too low, flue gases will spill from the barometric damper and trip the safety switch. This controls combustion air to the burner allowing the supply of the proper amount of fuel by maintaining the outlet draft pressure. On drafthood-type equipment, it replaces the drafthood and connects equipment to the flue, rather than isolating the flue. This allows it to control venting and combustion air to equipment and maintain stable combustion. The MG-1 is sensitive to as little as a -.005-in. Its ability to relieve downdraft or positive pressure is beneficial because a safety spill switch can be added to turn off equipment if there is a downdraft, or more importantly if the flue is restricted or blocked. But the double-acting barometric damper is still helpful. Other than water heaters, there currently aren’t many standing pilot appliances. The original reason to relieve downdrafts was to prevent standing pilots from blowing out. The Field Controls Double-Acting Barometric Type MG-1 Damper differs from its single-acting cousin in that not only does it control updrafts, but it also relieves downdrafts.